Picture of the family as saved in the library, model only (one fixed view). It does not change when another type is chosen.
Technical viewThe same family with its connectors, reference lines and dimension labels showing

The family editor's view: connectors, reference planes and labelled dimensions are showing.

Electrical · Electrical Equipment · Boards and panels

Lighting Power Board

ID IBIM-E-ELE-LIGHTING-POWER-BOARD-R25 · file IBIM-E-ELE-Lighting Power Board-R25.rfa

Revit
2025
Types
1
Hosting
Not hosted (placed on a level)
Connectors
1
Revit category
Electrical Equipment

8 checks passed. See what was checked

Request access How to use in Revit

Available on request. Nothing is downloaded or loaded into Revit from this page.

Types

This family has one type: 600x300.

Parameters of type “600x300”

57 parameters. Values are those saved in the library file for the selected type. An instance parameter shows its default; it is set per placed element in a project.

3 parameters of the file for authorship or contact details (author, website, e-mail and similar) are not shown.

ParameterValueUnitsScopeCan be edited
Constraints
Default Elevation0.0mmTypeYes
Construction
IBiM_VDA_Cable EntryTop & BottomTextTypeYes
IBiM_VDA_Forms1TextTypeYes
IBiM_VDA_IP42TextTypeYes
IBiM_VDA_Modules1TextTypeYes
Dimensions
IBiM_VDA_Depth300.0mmInstanceYes
IBiM_VDA_Height1000.0mmInstanceYes
IBiM_VDA_Width600.0mmInstanceYes
Electrical
IBiM_VDA_Load ClassificationNo valueLoad classificationTypeYes
IBiM_VDA_Number of Poles3Whole numberTypeYes
IBiM_VDA_Rated Current (In)0.00 AATypeYes
IBiM_VDA_Rated Frequency (F)50 HzTextTypeYes
IBiM_VDA_Rated Voltage (Ue)400.00 VVTypeYes
Voltage CommentsNo valueTextTypeYes
Wattage CommentsNo valueTextTypeYes
Electrical - Circuiting
BussingNo valueTextTypeYes
Circuit NamingNo value—InstanceYes
Circuit PrefixNo valueTextInstanceYes
Circuit Prefix SeparatorNo valueTextInstanceYes
Distribution SystemNo value—InstanceYes
FeedNo valueTextInstanceYes
Feed Through LugsNoYes / NoInstanceYes
Ground BusNo valueYes / NoTypeYes
MainsNo valueAInstanceYes
Mains TypeNo valueTextTypeYes
Max Number of Single Pole BreakersNo valueWhole numberInstanceYes
MCB Rating1.00 AAInstanceYes
ModificationsNo valueTextInstanceYes
Neutral BusNo valueYes / NoTypeYes
Neutral RatingNo value%TypeYes
Short Circuit Rating CommentsNo valueTextInstanceYes
SubFeed LugsNoYes / NoInstanceYes
General
EnclosureNo valueTextInstanceYes
IBiM_VDA_LocationIndoorTextTypeYes
IBiM_VDA_Manufacturer country---TextTypeYes
IBiM_VDA_Manufacturer name---TextTypeYes
IBiM_VDA_OperationFrontTextTypeYes
IBiM_VDA_Switchboard_TypeWall MountedTextTypeYes
MountingNo valueTextInstanceYes
Panel NameDP-01TextInstanceYes
Graphics
IBiM_VDA_Indication_PhaseYesYes / NoInstanceYes
IBiM_VDA_Label_Width300.0mmInstanceYes
MEP Maintenance sharedYesYes / NoInstanceYes
Identity Data
Assembly CodeNo valueTextTypeYes
CostNo valuecurrencyTypeYes
DescriptionNo valueTextTypeYes
KeynoteNo valueTextTypeYes
ManufacturerNo valueTextTypeYes
ModelNo valueTextTypeYes
Type CommentsLGT&PO DBTextTypeYes
Type ImageNo valueImageTypeYes
IFC Parameters
Export Type to IFC AsNo valueTextTypeYes
Type IFC Predefined TypeNo valueTextTypeYes
Materials and Finishes
IBiM_VDA_CoatingEpoxy powderTextTypeYes
IBiM_VDA_ColorNo valueMaterialTypeYes
IBiM_VDA_Material MainElectro-Galvanised steel sheetTextTypeYes
IBiM_VDA_ThicknessMinimum 50 MicronsTextTypeYes

Category, hosting and compatibility

Revit category
Electrical Equipment
Catalogue classification
Electrical › Electrical Equipment › Boards and panels
Hosting
Not hosted (placed on a level)
Connectors
  • Electrical, power - unbalanced
Revit version
Saved in the Revit 2025 format. It opens in Revit 2025 and in later versions, which upgrade it on opening. Revit versions before 2025 cannot open it.
Built from
1 solid form, 8 nested families

What was checked

8 passed, 5 not checked. Each line says what was looked at and what was found. A passed check is not a statement that the family suits a particular project or meets a standard.

  • Passed
    Opens and saves in Revit 2025

    Opened by Revit 2025 and saved without an error.

  • Passed
    No imported CAD geometry

    None found.

  • Passed
    Types, parameters and connectors kept by the clean-up

    1 type(s), 60 parameter(s), 1 connector(s) before and after. 3 unused item(s) were purged.

  • Passed
    File name follows the iBIM naming standard

    IBIM-E-ELE-Lighting Power Board-R25

  • Passed
    Preview picture made from the model

    Rendered from the family's 3D view, model only.

  • Passed
    Revit category matches the catalogue classification

    Revit category: Electrical Equipment.

  • Passed
    Connectors

    1 connector(s) found.

  • Passed
    Types are named

    1 named type(s).

  • Not checked
    Loading and placing in a project

    The family was opened on its own. It was not loaded into a project, placed or connected to a system.

  • Not checked
    Schedules and tags

    Whether the parameters report correctly in schedules and tags was not tested.

  • Not checked
    Sizes against product data

    Dimensions and performance values were not compared with any manufacturer's or standard's data.

  • Not checked
    Performance in large models

    File weight in a full project model was not measured.

  • Not checked
    Classification codes

    Uniclass, COBie or other classification data in the family was not reviewed.

File checked
IBIM-E-ELE-Lighting Power Board-R25.rfa
Fingerprint
95c954126727 first 12 characters of the file's SHA-256
Checked on
2026-10-12
Checked with
Revit 2025 (build 25.5.0.57)
File size
2048 KB
History
3 unused items were removed when the library copy was made.

Availability and next step

Availability
On request. Our team checks each request and replies within one business day. This website has no download.
Permitted use
Not stated on this page. The terms are agreed with iBIM Group when access is given.

Request access How to use in Revit

  1. FindThe catalogue
  2. InspectThis page
  3. Select typesShowing “600x300”
  4. Configure a working copyNot available on the website
  5. ValidateThe checks above cover the library file only
  6. Load into RevitAn explicit step in Revit, after access

How to use a family in Revit

  1. Find and inspect. Open a family here to see its types, parameters, hosting and what was checked. Browsing this website never loads anything into a Revit project.
  2. Request access. Use Request access on the family's page. Our team checks the request and replies within one business day. No file is sent automatically.
  3. With the iBIM Revit plug-in. Open the iBIM tab > iBIM Family > Family Library, choose the family and load it into your model. A family that is already in the model is never overwritten.
  4. Without the plug-in. Load the family file we send you with Revit's own Insert > Load Family.

Families are saved in the Revit version shown on each page. Revit cannot open a family saved in a newer version.