Picture of the family as saved in the library, model only (one fixed view). It does not change when another type is chosen.
Technical viewThe same family with its connectors, reference lines and dimension labels showing

The family editor's view: connectors, reference planes and labelled dimensions are showing.

Supports · Supports & Hangers · Cable tray supports

Cable Tray Hangers Parallel C Steel

ID IBIM-E-SUP-CABLE-TRAY-HANGERS-PARALLEL-C-STEEL · file IBIM-E-SUP-Cable Tray Hangers Parallel C Steel-R25.rfa

Revit
2025
Types
4
Hosting
Not hosted (placed on a level)
Connectors
0
Revit category
Duct Accessories

6 checks passed. See what was checked

Request access How to use in Revit

Available on request. Nothing is downloaded or loaded into Revit from this page.

Types

How the types differ

14 parameters out of 32 have a different value in at least one type.

ParameterC20x40, Ty8C20x40, Ty10C30x40, Ty10C30x50, Ty12
Suppport_Hole Diameter mm8.010.010.012.0
WasherFlat_Thinkness mm1.62.02.02.5
ThreadRod_Diameter mm8.410.510.513.0
CSteel_Total Length mm500.0300.0300.0300.0
Element_Width mm400.0200.0200.0200.0
DistanceCabletrayToCabletray mm300.0200.0200.0200.0
ElementBottomToFloor mm800.0500.0500.0500.0
CSteel _FaceWidth mm40.040.040.050.0
CSteel_Height mm20.020.030.030.0
CSteel_Thickness mm1.51.51.52.0
HexaNuts_Thickness mm6.58.08.010.0
Washer_Thickness mm1.62.02.02.5
DSC_BoltsNut_TypeM8M10M10M12
DSC_Csteel_TypeC20x40C20x40C30x40C30x50

Parameters of type “C20x40, Ty8”

32 parameters. Values are those saved in the library file for the selected type. An instance parameter shows its default; it is set per placed element in a project.

1 parameter of the file for authorship or contact details (author, website, e-mail and similar) is not shown.

ParameterValueUnitsScopeCan be edited
Constraints
Default Elevation0.0mmTypeYes
Data
CSteel_Total Length500.0mmInstanceNoSet by a formula in the family
Dimensions
Distance125.0mmTypeYes
Distance225.0mmTypeYes
DistanceCabletrayToCabletray300.0mmInstanceYes
Element_Width400.0mmInstanceYes
ElementBottomToFloor800.0mmInstanceYes
ThreadRod_Extend10.0mmTypeYes
General
CSteel _FaceWidth40.0mmInstanceNoSet by a formula in the family
CSteel_Height20.0mmInstanceNoSet by a formula in the family
CSteel_Thickness1.5mmInstanceNoSet by a formula in the family
HexaNuts_Thickness6.5mmInstanceNoSet by a formula in the family
Washer_Thickness1.6mmInstanceNoSet by a formula in the family
Graphics
Use Annotation ScaleNo valueYes / NoInstanceYes
Identity Data
Assembly CodeNo valueTextTypeYes
CostNo value₫TypeYes
DescriptionNo valueTextTypeYes
KeynoteNo valueTextTypeYes
ManufacturerNo valueTextTypeYes
ModelNo valueTextTypeYes
Type CommentsNo valueTextTypeYes
Type ImageNo valueImageTypeYes
IFC Parameters
Export Type to IFC AsNo valueTextTypeYes
Type IFC Predefined TypeNo valueTextTypeYes
Other
Suppport_Hole Diameter8.0mmInstanceNoSet by a formula in the family
ThreadRod_Diameter8.4mmInstanceNoSet by a formula in the family
WasherFlat_Thinkness1.6mmInstanceNoSet by a formula in the family
Text
DSC_BoltsNut_TypeM8TextTypeYes
DSC_Csteel_TypeC20x40TextTypeYes
DSC_LookupTable1DSC_DuctAcc_FlatWasher_DIN 125TextTypeNoSet by a formula in the family
DSC_LookupTable2DSC_C Steel_Re19TextTypeNoSet by a formula in the family
DSC_LookupTable3DSC_Hexa Nuts_DIN934TextTypeNoSet by a formula in the family

Category, hosting and compatibility

Revit category
Duct Accessories
Catalogue classification
Supports › Supports & Hangers › Cable tray supports
Hosting
Not hosted (placed on a level)
Connectors
None found
Revit version
Saved in the Revit 2025 format. It opens in Revit 2025 and in later versions, which upgrade it on opening. Revit versions before 2025 cannot open it.
Built from
2 solid forms, 8 nested families

What was checked

6 passed, 7 not checked. Each line says what was looked at and what was found. A passed check is not a statement that the family suits a particular project or meets a standard.

  • Passed
    Opens and saves in Revit 2025

    Opened by Revit 2025, upgraded from the Revit 2019 format, and saved without an error.

  • Passed
    No imported CAD geometry

    None found.

  • Passed
    Types, parameters and connectors kept by the clean-up

    4 type(s), 33 parameter(s), 0 connector(s) before and after. 0 unused item(s) were purged.

  • Passed
    File name follows the iBIM naming standard

    IBIM-E-SUP-Cable Tray Hangers Parallel C Steel-R25

  • Passed
    Preview picture made from the model

    Rendered from the family's 3D view, model only.

  • Not checked
    Revit category matches the catalogue classification

    Revit category: Duct Accessories. No single Revit category is expected for 'Supports & Hangers'.

  • Not checked
    Connectors

    None found. This kind of family does not need one.

  • Passed
    Types are named

    4 named type(s).

  • Not checked
    Loading and placing in a project

    The family was opened on its own. It was not loaded into a project, placed or connected to a system.

  • Not checked
    Schedules and tags

    Whether the parameters report correctly in schedules and tags was not tested.

  • Not checked
    Sizes against product data

    Dimensions and performance values were not compared with any manufacturer's or standard's data.

  • Not checked
    Performance in large models

    File weight in a full project model was not measured.

  • Not checked
    Classification codes

    Uniclass, COBie or other classification data in the family was not reviewed.

File checked
IBIM-E-SUP-Cable Tray Hangers Parallel C Steel-R25.rfa
Fingerprint
c37de87dd893 first 12 characters of the file's SHA-256
Checked on
2026-10-12
Checked with
Revit 2025 (build 25.5.0.57)
File size
952 KB
History
Upgraded from the Revit 2019 format. 0 unused items were removed when the library copy was made.

Availability and next step

Availability
On request. Our team checks each request and replies within one business day. This website has no download.
Permitted use
Not stated on this page. The terms are agreed with iBIM Group when access is given.

Request access How to use in Revit

  1. FindThe catalogue
  2. InspectThis page
  3. Select typesShowing “C20x40, Ty8”
  4. Configure a working copyNot available on the website
  5. ValidateThe checks above cover the library file only
  6. Load into RevitAn explicit step in Revit, after access

How to use a family in Revit

  1. Find and inspect. Open a family here to see its types, parameters, hosting and what was checked. Browsing this website never loads anything into a Revit project.
  2. Request access. Use Request access on the family's page. Our team checks the request and replies within one business day. No file is sent automatically.
  3. With the iBIM Revit plug-in. Open the iBIM tab > iBIM Family > Family Library, choose the family and load it into your model. A family that is already in the model is never overwritten.
  4. Without the plug-in. Load the family file we send you with Revit's own Insert > Load Family.

Families are saved in the Revit version shown on each page. Revit cannot open a family saved in a newer version.