Picture of the family as saved in the library, model only (one fixed view). It does not change when another type is chosen.
Technical viewThe same family with its connectors, reference lines and dimension labels showing

The family editor's view: connectors, reference planes and labelled dimensions are showing.

Supports · Supports & Hangers · Cable tray supports

Hanger Clamp

ID IBIM-E-SUP-HANGER-CLAMP-R25 · file IBIM-E-SUP-Hanger Clamp-R25.rfa

Revit
2025
Types
1
Hosting
Not hosted (placed on a level)
Connectors
0
Revit category
Duct Accessories

6 checks passed. See what was checked

Request access How to use in Revit

Available on request. Nothing is downloaded or loaded into Revit from this page.

Types

This family has one type: Ty8.

Parameters of type “Ty8”

27 parameters. Values are those saved in the library file for the selected type. An instance parameter shows its default; it is set per placed element in a project.

1 parameter of the file for authorship or contact details (author, website, e-mail and similar) is not shown.

ParameterValueUnitsScopeCan be edited
Constraints
Default Elevation0.0mmTypeYes
Data
BoltNuts_Diameter8.0mmInstanceNoSet by a formula in the family
HexaNuts_Thickness6.5mmInstanceNoSet by a formula in the family
ThreadRod_Extend10.0mmTypeYes
WasherFlat_Thickness1.6mmInstanceNoSet by a formula in the family
Dimensions
Element_Height100.0mmInstanceYes
Element_Width100.0mmInstanceYes
ElemetBottomToFloor500.0mmInstanceYes
HangerClamp_FaceWidth25.0mmTypeYes
HangerClamp_Height125.0mmInstanceNoSet by a formula in the family
HangerClamp_Thickness2.0mmTypeYes
HangerClamp_TotalHeight160.0mmInstanceNoSet by a formula in the family
HangerClamp_Width110.0mmInstanceNoSet by a formula in the family
Graphics
Use Annotation ScaleNo valueYes / NoInstanceYes
Identity Data
Assembly CodeNo valueTextTypeYes
CostNo valuecurrencyTypeYes
DescriptionNo valueTextTypeYes
KeynoteNo valueTextTypeYes
ManufacturerNo valueTextTypeYes
ModelNo valueTextTypeYes
Type CommentsNo valueTextTypeYes
Type ImageNo valueImageTypeYes
IFC Parameters
Export Type to IFC AsNo valueTextTypeYes
Type IFC Predefined TypeNo valueTextTypeYes
Text
DSC_BoltsNuts_TypeM8TextTypeYes
DSC_LookupTable1DSC_DuctAcc_FlatWasher_DIN 125TextTypeNoSet by a formula in the family
DSC_LookupTable2DSC_DuctAcc_Hexa Nuts_DIN934TextTypeNoSet by a formula in the family

Category, hosting and compatibility

Revit category
Duct Accessories
Catalogue classification
Supports › Supports & Hangers › Cable tray supports
Hosting
Not hosted (placed on a level)
Connectors
None found
Revit version
Saved in the Revit 2025 format. It opens in Revit 2025 and in later versions, which upgrade it on opening. Revit versions before 2025 cannot open it.
Built from
2 solid forms, 6 nested families

What was checked

6 passed, 7 not checked. Each line says what was looked at and what was found. A passed check is not a statement that the family suits a particular project or meets a standard.

  • Passed
    Opens and saves in Revit 2025

    Opened by Revit 2025, upgraded from the Revit 2019 format, and saved without an error.

  • Passed
    No imported CAD geometry

    None found.

  • Passed
    Types, parameters and connectors kept by the clean-up

    1 type(s), 28 parameter(s), 0 connector(s) before and after. 17 unused item(s) were purged.

  • Passed
    File name follows the iBIM naming standard

    IBIM-E-SUP-Hanger Clamp-R25

  • Passed
    Preview picture made from the model

    Rendered from the family's 3D view, model only.

  • Not checked
    Revit category matches the catalogue classification

    Revit category: Duct Accessories. No single Revit category is expected for 'Supports & Hangers'.

  • Not checked
    Connectors

    None found. This kind of family does not need one.

  • Passed
    Types are named

    1 named type(s).

  • Not checked
    Loading and placing in a project

    The family was opened on its own. It was not loaded into a project, placed or connected to a system.

  • Not checked
    Schedules and tags

    Whether the parameters report correctly in schedules and tags was not tested.

  • Not checked
    Sizes against product data

    Dimensions and performance values were not compared with any manufacturer's or standard's data.

  • Not checked
    Performance in large models

    File weight in a full project model was not measured.

  • Not checked
    Classification codes

    Uniclass, COBie or other classification data in the family was not reviewed.

File checked
IBIM-E-SUP-Hanger Clamp-R25.rfa
Fingerprint
1d104ab2fcd3 first 12 characters of the file's SHA-256
Checked on
2026-10-12
Checked with
Revit 2025 (build 25.5.0.57)
File size
768 KB
History
Upgraded from the Revit 2019 format. 17 unused items were removed when the library copy was made.

Availability and next step

Availability
On request. Our team checks each request and replies within one business day. This website has no download.
Permitted use
Not stated on this page. The terms are agreed with iBIM Group when access is given.

Request access How to use in Revit

  1. FindThe catalogue
  2. InspectThis page
  3. Select typesShowing “Ty8”
  4. Configure a working copyNot available on the website
  5. ValidateThe checks above cover the library file only
  6. Load into RevitAn explicit step in Revit, after access

How to use a family in Revit

  1. Find and inspect. Open a family here to see its types, parameters, hosting and what was checked. Browsing this website never loads anything into a Revit project.
  2. Request access. Use Request access on the family's page. Our team checks the request and replies within one business day. No file is sent automatically.
  3. With the iBIM Revit plug-in. Open the iBIM tab > iBIM Family > Family Library, choose the family and load it into your model. A family that is already in the model is never overwritten.
  4. Without the plug-in. Load the family file we send you with Revit's own Insert > Load Family.

Families are saved in the Revit version shown on each page. Revit cannot open a family saved in a newer version.