Picture of the family as saved in the library, model only (one fixed view). It does not change when another type is chosen.
Technical viewThe same family with its connectors, reference lines and dimension labels showing

The family editor's view: connectors, reference planes and labelled dimensions are showing.

Mechanical · Air Terminals · Diffusers

Round Diffuser DFCI

ID IBIM-M-ART-ROUND-DIFFUSER-DFCI-R25 · file IBIM-M-ART-Round Diffuser DFCI-R25.rfa

Revit
2025
Types
1
Hosting
Not hosted (placed on a level)
Connectors
1
Revit category
Air Terminals

8 checks passed. See what was checked

Request access How to use in Revit

Available on request. Nothing is downloaded or loaded into Revit from this page.

Types

This family has one type: INVALID TYPE - Use Load Family and Type Catalog instead.

Parameters of type “INVALID TYPE - Use Load Family and Type Catalog instead”

84 parameters. Values are those saved in the library file for the selected type. An instance parameter shows its default; it is set per placed element in a project.

9 parameters of the file for authorship or contact details (author, website, e-mail and similar) are not shown.

ParameterValueUnitsScopeCan be edited
Constraints
Default Elevation0.000 mmmmTypeYes
Data
Ak shared1.400000generalTypeYes
c1 shared0.001601generalTypeNoSet by a formula in the family
c2 shared-3.153000generalTypeNoSet by a formula in the family
c3 shared-153.100000generalTypeNoSet by a formula in the family
c4 shared-77.450000generalTypeNoSet by a formula in the family
c5 shared82.340000generalTypeNoSet by a formula in the family
c6 shared-6.299000generalTypeNoSet by a formula in the family
c7 shared0.014850generalTypeNoSet by a formula in the family
c8 shared-0.807900generalTypeNoSet by a formula in the family
Q shared150.000000generalInstanceNoSet by a formula in the family
Dimensions
Duct Diameter shared150.0 mmmmTypeYes
Neck Length shared45.400 mmmmTypeYes
General
Date of publishing sharedNo valueTextTypeYes
Design country sharedSpainTextTypeYes
Edition number shared1Whole numberTypeYes
Manufacturer country sharedSpainTextTypeYes
Manufacturer name sharedAirzoneTextTypeYes
Nominal height shared0.000 mmmmTypeYes
Nominal width shared0.000 mmmmTypeYes
Product family sharedAirQTextTypeYes
Product group sharedAir diffusor TextTypeYes
Product SKU sharedAirQ_DFCI_WNTextTypeYes
Region Africa sharedMATextTypeYes
Region Antarctica sharedNoneTextTypeYes
Region Asia sharedNoneTextTypeYes
Region Europe sharedAD, AL, AT, AX, BA, BE, BG, BY, CH, CY, CZ, DE, DK, EE, ES, FI, FO, FR, GB, GG, GI, GR, HR, HU, IE, IM, IS, IT, JE, LI, LT, LU, LV, MC, MD, ME, MK, MT, NL, NO, PL, PT, RO, RS, RU, SE, SI, SJ, SK, SM, UA, VATextTypeYes
Region Middle East sharedNoneTextTypeYes
Region North America sharedNoneTextTypeYes
Region Oceania sharedNoneTextTypeYes
Region South America sharedNoneTextTypeYes
Weight Net (Kg) shared0TextTypeYes
Identity Data
Assembly CodeNo valueTextTypeYes
Compatible Accesories sharedInsulated flexible duct (TFTA) and non-insulated flexible duct (TFST)TextTypeNoSet by a formula in the family
CostNo valuecurrencyTypeYes
DescriptionRound diffuserTextTypeNoSet by a formula in the family
EAN code sharedNo valueTextTypeYes
Fixing sharedSecurity mechanical attachment. Mounting bracketTextTypeNoSet by a formula in the family
KeynoteNo valueTextTypeYes
Long Description sharedRound diffuser DFCI to supply air in 4 directions that enables the air supply. Easy to disassemble to facilitate its maintenance. Designed to be installed in ceiling.TextTypeNoSet by a formula in the family
ManufacturerAIRZONETextTypeNoSet by a formula in the family
ModelINVALID – Type not loaded via type catalogTextTypeNoSet by a formula in the family
Product Code sharedINVALID – Type not loaded via type catalogTextTypeYes
Product Comments sharedRefer to technical documentation for further detailsTextTypeNoSet by a formula in the family
Product Guid shared7eec4590-87ae-44f2-a62c-c54f63c288ffTextTypeYes
Type CommentsNo valueTextTypeYes
Type ImageNo valueImageTypeYes
Type Image Comments sharedImage available in product documentation downloadTextTypeNoSet by a formula in the family
Youtube clip sharedNo valueTextTypeYes
IFC Parameters
BIMobject category sharedDuctworkTextTypeYes
COBIe Type Category sharedNo valueTextTypeYes
Export Type to IFC AsNo valueTextTypeYes
IFC Classification sharedDistribution Control ElementTextTypeYes
Masterformat 2014 Code shared23 09 33TextTypeYes
Masterformat 2014 Description sharedElectric and Electronic Control System for HVACTextTypeYes
NBS Reference Code shared65-80TextTypeYes
NBS Reference Description sharedAir Conditioning SystemsTextTypeYes
OmniClass Code shared23-33 49 00TextTypeYes
OmniClass Description sharedHVAC DuctworkTextTypeYes
Type IFC Predefined TypeNo valueTextTypeYes
Uniclass 1.4 Code sharedJU30TextTypeYes
Uniclass 1.4 Description sharedAir conditioning systemsTextTypeYes
Uniclass 2.0 Code sharedSS-65-80TextTypeYes
Uniclass 2.0 Description sharedAir Conditioning SystemsTextTypeYes
Uniclass 2015 Code sharedSs_65_80TextTypeYes
Uniclass 2015 Name sharedAir conditioning systemsTextTypeYes
Uniformat II Code sharedD3090TextTypeYes
Uniformat II Description sharedOther HVAC Systems & EquipmentTextTypeYes
UNSPSC Code shared40101505TextTypeYes
Materials and Finishes
Accessories Material sharedNo valueMaterialTypeYes
Finish sharedWhite (RAL 9010)TextTypeYes
Main Material sharedNo valueMaterialTypeYes
Material main sharedAluminiumTextTypeYes
Material secondary sharedGalvanized steelTextTypeYes
Mechanical - Flow
Effective Area shared140.00 cm²cm²TypeNoSet by a formula in the family
Flow shared150.0000 m³/hm³/hInstanceYes
Max Flow1500.0000 m³/hm³/hTypeYes
Min Flow150.0000 m³/hm³/hTypeYes
Pressure Drop shared12.469015 PaPaInstanceNoSet by a formula in the family
Sound Level in dB(A) shared13.000000generalInstanceNoSet by a formula in the family
Throw Distance shared1697.000 mmmmInstanceNoSet by a formula in the family
Velocity shared2.98 m/sm/sInstanceNoSet by a formula in the family
Model Properties
Disclaimer sharedAll information provided in this model is reviewed before being published. However, Airzone cannot guarantee this model is error-free, therefore users are strongly encouraged to check for technical documentation and updatesTextTypeNoSet by a formula in the family
Revit Model Version shared1.0TextTypeNoSet by a formula in the family

Category, hosting and compatibility

Revit category
Air Terminals
Catalogue classification
Mechanical › Air Terminals › Diffusers
Hosting
Not hosted (placed on a level)
Connectors
  • Duct, round 150 mm, supply air
Revit version
Saved in the Revit 2025 format. It opens in Revit 2025 and in later versions, which upgrade it on opening. Revit versions before 2025 cannot open it.
Built from
5 nested families

What was checked

8 passed, 5 not checked. Each line says what was looked at and what was found. A passed check is not a statement that the family suits a particular project or meets a standard.

  • Passed
    Opens and saves in Revit 2025

    Opened by Revit 2025, upgraded from the Revit 2016 format, and saved without an error.

  • Passed
    No imported CAD geometry

    None found.

  • Passed
    Types, parameters and connectors kept by the clean-up

    1 type(s), 93 parameter(s), 1 connector(s) before and after. 0 unused item(s) were purged.

  • Passed
    File name follows the iBIM naming standard

    IBIM-M-ART-Round Diffuser DFCI-R25

  • Passed
    Preview picture made from the model

    Rendered from the family's 3D view, model only.

  • Passed
    Revit category matches the catalogue classification

    Revit category: Air Terminals.

  • Passed
    Has a connector to join a system

    1 connector(s): Duct, round 150 mm, supply air.

  • Passed
    Types are named

    1 named type(s).

  • Not checked
    Loading and placing in a project

    The family was opened on its own. It was not loaded into a project, placed or connected to a system.

  • Not checked
    Schedules and tags

    Whether the parameters report correctly in schedules and tags was not tested.

  • Not checked
    Sizes against product data

    Dimensions and performance values were not compared with any manufacturer's or standard's data.

  • Not checked
    Performance in large models

    File weight in a full project model was not measured.

  • Not checked
    Classification codes

    Uniclass, COBie or other classification data in the family was not reviewed.

File checked
IBIM-M-ART-Round Diffuser DFCI-R25.rfa
Fingerprint
da3d05f34dac first 12 characters of the file's SHA-256
Checked on
2026-10-12
Checked with
Revit 2025 (build 25.5.0.57)
File size
816 KB
History
Upgraded from the Revit 2016 format. 0 unused items were removed when the library copy was made.

Availability and next step

Availability
On request. Our team checks each request and replies within one business day. This website has no download.
Permitted use
Not stated on this page. The terms are agreed with iBIM Group when access is given.

Request access How to use in Revit

  1. FindThe catalogue
  2. InspectThis page
  3. Select typesShowing “INVALID TYPE - Use Load Family and Type Catalog instead”
  4. Configure a working copyNot available on the website
  5. ValidateThe checks above cover the library file only
  6. Load into RevitAn explicit step in Revit, after access

How to use a family in Revit

  1. Find and inspect. Open a family here to see its types, parameters, hosting and what was checked. Browsing this website never loads anything into a Revit project.
  2. Request access. Use Request access on the family's page. Our team checks the request and replies within one business day. No file is sent automatically.
  3. With the iBIM Revit plug-in. Open the iBIM tab > iBIM Family > Family Library, choose the family and load it into your model. A family that is already in the model is never overwritten.
  4. Without the plug-in. Load the family file we send you with Revit's own Insert > Load Family.

Families are saved in the Revit version shown on each page. Revit cannot open a family saved in a newer version.