Picture of the family as saved in the library, model only (one fixed view). It does not change when another type is chosen.
Technical viewThe same family with its connectors, reference lines and dimension labels showing

The family editor's view: connectors, reference planes and labelled dimensions are showing.

Plumbing · Pipe Accessories · Other valves

Landing Valve

ID IBIM-P-PIA-LANDING-VALVE-R25 · file IBIM-P-PIA-Landing Valve-R25.rfa

Revit
2025
Types
2
Hosting
Not hosted (placed on a level)
Connectors
1
Revit category
Pipe Accessories

8 checks passed. See what was checked

Request access How to use in Revit

Available on request. Nothing is downloaded or loaded into Revit from this page.

Types

No parameter value differs between the 2 types in this file. They may differ in something that is not a parameter, which this page cannot show.

Parameters of type “Fire Hydrant”

80 parameters. Values are those saved in the library file for the selected type. An instance parameter shows its default; it is set per placed element in a project.

5 parameters of the file for authorship or contact details (author, website, e-mail and similar) are not shown.

ParameterValueUnitsScopeCan be edited
Constraints
Default Elevation0.0mmTypeYes
Dimensions
Angle 3 shared90.00°°TypeYes
CT12Whole numberTypeYes
CT22Whole numberTypeYes
CT32Whole numberTypeYes
Diameter50.0 mmmmInstanceYes
Diameter 1 shared50.0mmInstanceNoSet by a formula in the family
Diameter 2 shared50.0mmInstanceNoSet by a formula in the family
Diameter 3 shared50.0mmInstanceNoSet by a formula in the family
Height177.0mmTypeYes
Length135.0mmTypeYes
Length 1 shared27.5mmInstanceNoSet by a formula in the family
Graphics
Use Annotation ScaleNo valueYes / NoInstanceYes
Identity Data
Article Description sharedFire hydrant with T-pieceTextTypeNoSet by a formula in the family
Article Type sharedNo valueTextTypeNoSet by a formula in the family
Assembly CodeNo valueTextTypeYes
CB-NL Class sharedNo valueTextTypeYes
CostNo valuecurrencyTypeYes
Custom sharedNoYes / NoTypeYes
DescriptionFire hydrant with T-pieceTextTypeNoSet by a formula in the family
EMCS Version2.0TextTypeNoSet by a formula in the family
ETIM Article Class sharedEC011418TextTypeYes
Family Version11.02TextTypeNoSet by a formula in the family
Function Code sharedNo valueTextInstanceYes
GTIN sharedNo valueTextTypeYes
Internal Art. No. sharedNo valueTextTypeYes
KeynoteNo valueTextTypeYes
LanguageNo valueTextTypeYes
ManufacturerUnspecifiedTextTypeNoSet by a formula in the family
Manufacturer Art. No. sharedNo valueTextTypeYes
MEPcontent Class sharedFIRE_HYDRANTTextTypeNoSet by a formula in the family
ModelNo valueTextTypeYes
Product Line sharedUnspecifiedTextTypeNoSet by a formula in the family
Revit Version2016TextTypeNoSet by a formula in the family
Stabu Code sharedNo valueTextTypeYes
Type CommentsNo valueTextTypeYes
Type ImageNo valueImageTypeYes
Wholesaler sharedNo valueTextTypeYes
Wholesaler Art. No. sharedNo valueTextTypeYes
IFC Parameters
Export Type to IFC AsNo valueTextTypeYes
IFCExportAsIfcFireSuppressionTerminalTypeTextTypeYes
IFCExportTypeFIREHYDRANTTextTypeYes
Type IFC Predefined TypeNo valueTextTypeYes
Materials and Finishes
CromNo valueMaterialTypeYes
Mechanical
K CoefficientNo valuegeneralTypeYes
K Coefficient TableNo valueTextTypeYes
Loss MethodNo valueWhole numberTypeYes
Other
BigLength25.0mmInstanceNoSet by a formula in the family
Is_M1_VisibleYesYes / NoInstanceNoSet by a formula in the family
Is_M2_VisibleYesYes / NoInstanceNoSet by a formula in the family
Is_M3_VisibleYesYes / NoInstanceNoSet by a formula in the family
Is_Sealing_Ring3_VisibleNoYes / NoInstanceNoSet by a formula in the family
LENGTH2 shared27.5mmInstanceNoSet by a formula in the family
LENGTH3 shared27.5mmInstanceNoSet by a formula in the family
M120.0mmInstanceNoSet by a formula in the family
M1_Radius26.3mmInstanceNoSet by a formula in the family
M1_Safe20.0mmInstanceNoSet by a formula in the family
M1_Void_Radius23.6mmInstanceNoSet by a formula in the family
M220.0mmInstanceNoSet by a formula in the family
M2_Radius26.3mmInstanceNoSet by a formula in the family
M2_Safe20.0mmInstanceNoSet by a formula in the family
M2_Void_Radius23.6mmInstanceNoSet by a formula in the family
M320.0mmInstanceNoSet by a formula in the family
M3_Radius26.3mmInstanceNoSet by a formula in the family
M3_Safe20.0mmInstanceNoSet by a formula in the family
M3_Void_Radius23.6mmInstanceNoSet by a formula in the family
MOD_Angle90.00°°InstanceNoSet by a formula in the family
RADIUS125.0mmInstanceYes
RADIUS225.0mmInstanceNoSet by a formula in the family
RADIUS325.0mmInstanceYes
RECT_Angle90.00°°InstanceNoSet by a formula in the family
Sealing_Ring1_Length4.0mmInstanceNoSet by a formula in the family
Sealing_Ring1_Radius27.6mmInstanceNoSet by a formula in the family
Sealing_Ring1_VisibilityNoYes / NoInstanceNoSet by a formula in the family
Sealing_Ring2_Length4.0mmInstanceNoSet by a formula in the family
Sealing_Ring2_Radius27.6mmInstanceNoSet by a formula in the family
Sealing_Ring2_VisibilityNoYes / NoInstanceNoSet by a formula in the family
Sealing_Ring3_Length4.0mmInstanceNoSet by a formula in the family
Sealing_Ring3_Radius27.6mmInstanceNoSet by a formula in the family
SmallLength25.0mmInstanceNoSet by a formula in the family

Category, hosting and compatibility

Revit category
Pipe Accessories
Catalogue classification
Plumbing › Pipe Accessories › Other valves
Hosting
Not hosted (placed on a level)
Connectors
  • Pipe, round 100 mm, fire protect dry
Revit version
Saved in the Revit 2025 format. It opens in Revit 2025 and in later versions, which upgrade it on opening. Revit versions before 2025 cannot open it.
Built from
2 solid forms, 2 voids, 11 nested families

What was checked

8 passed, 5 not checked. Each line says what was looked at and what was found. A passed check is not a statement that the family suits a particular project or meets a standard.

  • Passed
    Opens and saves in Revit 2025

    Opened by Revit 2025, upgraded from the Revit 2019 format, and saved without an error.

  • Passed
    No imported CAD geometry

    None found.

  • Passed
    Types, parameters and connectors kept by the clean-up

    2 type(s), 85 parameter(s), 1 connector(s) before and after. 30 unused item(s) were purged.

  • Passed
    File name follows the iBIM naming standard

    IBIM-P-PIA-Landing Valve-R25

  • Passed
    Preview picture made from the model

    Rendered from the family's 3D view, model only.

  • Passed
    Revit category matches the catalogue classification

    Revit category: Pipe Accessories.

  • Passed
    Has a connector to join a system

    1 connector(s): Pipe, round 100 mm, fire protect dry.

  • Passed
    Types are named

    2 named type(s).

  • Not checked
    Loading and placing in a project

    The family was opened on its own. It was not loaded into a project, placed or connected to a system.

  • Not checked
    Schedules and tags

    Whether the parameters report correctly in schedules and tags was not tested.

  • Not checked
    Sizes against product data

    Dimensions and performance values were not compared with any manufacturer's or standard's data.

  • Not checked
    Performance in large models

    File weight in a full project model was not measured.

  • Not checked
    Classification codes

    Uniclass, COBie or other classification data in the family was not reviewed.

File checked
IBIM-P-PIA-Landing Valve-R25.rfa
Fingerprint
046bcc4e315a first 12 characters of the file's SHA-256
Checked on
2026-10-12
Checked with
Revit 2025 (build 25.5.0.57)
File size
1384 KB
History
Upgraded from the Revit 2019 format. 30 unused items were removed when the library copy was made.

Availability and next step

Availability
On request. Our team checks each request and replies within one business day. This website has no download.
Permitted use
Not stated on this page. The terms are agreed with iBIM Group when access is given.

Request access How to use in Revit

  1. FindThe catalogue
  2. InspectThis page
  3. Select typesShowing “Fire Hydrant”
  4. Configure a working copyNot available on the website
  5. ValidateThe checks above cover the library file only
  6. Load into RevitAn explicit step in Revit, after access

How to use a family in Revit

  1. Find and inspect. Open a family here to see its types, parameters, hosting and what was checked. Browsing this website never loads anything into a Revit project.
  2. Request access. Use Request access on the family's page. Our team checks the request and replies within one business day. No file is sent automatically.
  3. With the iBIM Revit plug-in. Open the iBIM tab > iBIM Family > Family Library, choose the family and load it into your model. A family that is already in the model is never overwritten.
  4. Without the plug-in. Load the family file we send you with Revit's own Insert > Load Family.

Families are saved in the Revit version shown on each page. Revit cannot open a family saved in a newer version.