Picture of the family as saved in the library, model only (one fixed view). It does not change when another type is chosen.
Technical viewThe same family with its connectors, reference lines and dimension labels showing

The family editor's view: connectors, reference planes and labelled dimensions are showing.

Fire Protection · Fire Protection Sprinklers · Sprinklers

Pendent sprinkler without cup, DN15 / DN20

Library name: Downward Sprinkler (Non Cap)

ID IBIM-P-SPR-DOWNWARD-SPRINKLER-NON-CAP-R25 · file IBIM-P-SPR-Downward Sprinkler (Non Cap)-R25.rfa

Revit
2025
Types
2
Hosting
Not hosted (placed on a level)
Connectors
1
Revit category
Sprinklers

8 checks passed. See what was checked

Request access How to use in Revit

Available on request. Nothing is downloaded or loaded into Revit from this page.

Types

How the types differ

4 parameters out of 25 have a different value in at least one type.

ParameterDN15DN20
Length Conector mm12.616.8
Nominal Diameter mm15.020.0
DN15YesNo
DN20NoYes

Parameters of type “DN20”

25 parameters. Values are those saved in the library file for the selected type. An instance parameter shows its default; it is set per placed element in a project.

2 parameters of the file for authorship or contact details (author, website, e-mail and similar) are not shown.

ParameterValueUnitsScopeCan be edited
Constraints
Default Elevation0.0mmTypeYes
Dimensions
Length Conector16.8mmTypeYes
Nominal Diameter20.0mmTypeYes
Fire Protection
CoverageNo valueWhole numberTypeYes
K-FactorNo valuegeneralTypeYes
OrificeNo valueWhole numberTypeYes
Orifice SizeNo valuemmTypeYes
Pressure ClassNo valueWhole numberTypeYes
ResponseNo valueWhole numberTypeYes
Temperature RatingNo value°CTypeYes
Identity Data
Assembly CodeNo valueTextTypeYes
CostNo valuecurrencyTypeYes
DescriptionNo valueTextTypeYes
KeynoteNo valueTextTypeYes
ManufacturerNo valueTextTypeYes
ModelNo valueTextTypeYes
Type CommentsNo valueTextTypeYes
Type ImageNo valueImageTypeYes
IFC Parameters
Export Type to IFC AsNo valueTextTypeYes
Type IFC Predefined TypeNo valueTextTypeYes
Materials and Finishes
Material BodyNo valueMaterialTypeYes
Material MercuryNo valueMaterialTypeYes
Mechanical
DiameterNo valuemmTypeYes
Visibility
DN15NoYes / NoTypeYes
DN20YesYes / NoTypeYes

Category, hosting and compatibility

Revit category
Sprinklers
Catalogue classification
Fire Protection › Fire Protection Sprinklers › Sprinklers
Hosting
Not hosted (placed on a level)
Connectors
  • Pipe, round 20 mm, fitting
Revit version
Saved in the Revit 2025 format. It opens in Revit 2025 and in later versions, which upgrade it on opening. Revit versions before 2025 cannot open it.
Built from
6 solid forms, 22 voids, 3 nested families

What was checked

8 passed, 5 not checked. Each line says what was looked at and what was found. A passed check is not a statement that the family suits a particular project or meets a standard.

  • Passed
    Opens and saves in Revit 2025

    Opened by Revit 2025, upgraded from the Revit 2019 format, and saved without an error.

  • Passed
    No imported CAD geometry

    None found.

  • Passed
    Types, parameters and connectors kept by the clean-up

    3 type(s), 27 parameter(s), 1 connector(s) before and after. 0 unused item(s) were purged.

  • Passed
    File name follows the iBIM naming standard

    IBIM-P-SPR-Downward Sprinkler (Non Cap)-R25

  • Passed
    Preview picture made from the model

    Rendered from the family's 3D view, model only.

  • Passed
    Revit category matches the catalogue classification

    Revit category: Sprinklers.

  • Passed
    Has a connector to join a system

    1 connector(s): Pipe, round 20 mm, fitting.

  • Passed
    Types are named

    2 named type(s).

  • Not checked
    Loading and placing in a project

    The family was opened on its own. It was not loaded into a project, placed or connected to a system.

  • Not checked
    Schedules and tags

    Whether the parameters report correctly in schedules and tags was not tested.

  • Not checked
    Sizes against product data

    Dimensions and performance values were not compared with any manufacturer's or standard's data.

  • Not checked
    Performance in large models

    File weight in a full project model was not measured.

  • Not checked
    Classification codes

    Uniclass, COBie or other classification data in the family was not reviewed.

File checked
IBIM-P-SPR-Downward Sprinkler (Non Cap)-R25.rfa
Fingerprint
b6580da27ae5 first 12 characters of the file's SHA-256
Checked on
2026-10-12
Checked with
Revit 2025 (build 25.5.0.57)
File size
984 KB
History
Upgraded from the Revit 2019 format. 0 unused items were removed when the library copy was made.

Availability and next step

Availability
On request. Our team checks each request and replies within one business day. This website has no download.
Permitted use
Not stated on this page. The terms are agreed with iBIM Group when access is given.

Request access How to use in Revit

  1. FindThe catalogue
  2. InspectThis page
  3. Select typesShowing “DN20”
  4. Configure a working copyNot available on the website
  5. ValidateThe checks above cover the library file only
  6. Load into RevitAn explicit step in Revit, after access

How to use a family in Revit

  1. Find and inspect. Open a family here to see its types, parameters, hosting and what was checked. Browsing this website never loads anything into a Revit project.
  2. Request access. Use Request access on the family's page. Our team checks the request and replies within one business day. No file is sent automatically.
  3. With the iBIM Revit plug-in. Open the iBIM tab > iBIM Family > Family Library, choose the family and load it into your model. A family that is already in the model is never overwritten.
  4. Without the plug-in. Load the family file we send you with Revit's own Insert > Load Family.

Families are saved in the Revit version shown on each page. Revit cannot open a family saved in a newer version.